组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
By combining polymer pen lithography (PPL) patterning with in situ polymerization, we report a straightforward and bottom-up approach for bench-top fabrication of microelectrode arrays (MEAs) with well-controlled dimensions. The as-fabricated MEAs can be used to electrodeposit prussian blue in situ and work as a biosensor for H2O2 with a detection limit as low as 5 nM at a sensitivity of 0.7 A cm-2 M-1.