2017

Detection of Nitric Oxide from Living Cells Using Polymeric Zinc Organic Framework-Derived Zinc Oxide Composite with Conducting Polymer.

Small (Weinheim an der Bergstrasse, Germany) Kim MY, Naveen MH, Gurudatt NG, Shim YB
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Sensitive and selective detection of nitric oxide (NO) in the human body is crucial since it has the vital roles in the physiological and pathological processes. This study reports a new type of electrochemical NO biosensor based on zinc-dithiooxamide framework derived porous ZnO nanoparticles and polyterthiophene-rGO composite. By taking advantage of the synergetic effect between ZnO and poly(TTBA-rGO) (TTBA = 3'-(p-benzoic acid)-2,2':5',2″-terthiophene, rGO = reduced graphene oxide) nanocomposite layer, the poly(TTBA-rGO)/ZnO sensor probe displays excellent electrocatalytic activity and explores to detect NO released from normal and cancer cell lines. The ZnO is immobilized on a composite layer of poly(TTBA-rGO). The highly porous ZnO offers a high electrolyte accessible surface area and high ion-electron transport rates that efficiently catalyze the NO reduction reaction. Amperometry with the modified electrode displays highly sensitive response and wide dynamic range of 0.019-76 × 10-6 m with the detection limit of 7.7 ± 0.43 × 10-9 m. The sensor probe is demonstrated to detect NO released from living cells by drug stimulation. The proposed sensor provides a powerful platform for the low detection limit that is feasible for real-time analysis of NO in a biological system.

关键词