2017

Hydrogen Peroxide Sensing Based on Inner Surfaces Modification of Solid-State Nanopore.

Nanoscale research letters Zhu L, Gu D, Liu Q
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

There are many techniques for the detection of molecules. But detection of molecules through solid-state nanopore in a solution is one of the promising, high-throughput, and low-cost technology used these days. In the present investigation, a solid-state nanopore platform was fabricated for the detection of hydrogen peroxide (H2O2), which is not only a label free product but also a significant participant in the redox reaction. We have successfully fabricated silicon nitride (Si3N4) nanopores with diameters of ~50 nm by using a focused Ga ion beam, the inner surface of the nanopore has been modified with horseradish peroxidase (HRP) by employing carbodiimide coupling chemistry. The immobilized HRP enzymes have ability to induce redox reactions in a single nanopore channel. Moreover, a real-time single aggregated ABTS•+ molecular translocation events were monitored and investigated. The designed solid-state nanopore biosensor is reversible and can be applied to detect H2O2 multiple times.

关键词