2018

New Intracellular Shikimic Acid Biosensor for Monitoring Shikimate Synthesis in Corynebacterium glutamicum.

ACS synthetic biology Liu C, Zhang B, Liu YM, Yang KQ, Liu SJ
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The quantitative monitoring of intracellular metabolites with in vivo biosensors provides an efficient means of identifying high-yield strains and observing product accumulation in real time. In this study, a shikimic acid (SA) biosensor was constructed from a LysR-type transcriptional regulator (ShiR) of Corynebacterium glutamicum. The SA biosensor specifically responded to the increase of intracellular SA concentration over a linear range of 19.5 ± 3.6 to 120.9 ± 1.2 fmole at the single-cell level. This new SA biosensor was successfully used to (1) monitor the SA production of different C. glutamicum strains; (2) develop a novel result-oriented high-throughput ribosome binding site screening and sorting strategy that was used for engineering high-yield shikimate-producing strains; and (3) engineer a whole-cell biosensor through the coexpression of the SA sensor and a shikimate transporter shiA gene in C. glutamicum RES167. This work demonstrated that a new intracellular SA biosensor is a valuable tool facilitating the fast development of microbial SA producer.

关键词