Highly effective target converting strategy for ultrasensitive electrochemical assay of Hg

The Analyst Lv J, Xie S, Cai W, Zhang J, Tang D, Tang Y
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

An electrochemical sensing system based on a highly effective mercuric ion (Hg2+) converting strategy and rolling circle amplification (RCA) is developed for the ultrasensitive detection of Hg2+. The Hg2+ converting strategy is implemented based on Hg2+ specific recognition thymine-Hg2+-thymine (T-Hg2+-T)-induced DNA strand displacement. First, polystyrene magnetic microspheres coated by AuNPs (Au@PSC) as a magnetic separator were labeled with ssDNA D1 (thymine-rich) and S1/D2 DNA duplex (guanine-rich S1). In the presence of Hg2+ and long ssDNA D3 (thymine-rich at the 5' end), the formation of a stable T-Hg2+-T structure between D2 and D3 pushes S1 out from the S1/D2 DNA duplex, realizing the conversion of input target Hg2+ into output S1. Thus, the total amount of output S1 is proportional to the amount of input Hg2+. Thereafter, the output S1 serves as the primer to perform RCA to obtain long guanine-rich ssDNA, which could be further hybridized with the capture DNA on the electrode surface. Subsequently, methylene blue (MB) as an electron mediator interacts with the ssDNA polymers via electrostatic binding to produce a detection signal. The electrochemical biosensor exhibits a wide linear range of 1 pM to 1 μM with a low detection limit of 0.684 pM. Importantly, this sensor can be successfully applied in water samples with good accuracy and excellent recovery, which indicates its potential for Hg2+ detection in the environment.

关键词