2018

Ultrasound-accelerated synthesis of gold nanoparticles modified choline chloride functionalized graphene oxide as a novel sensitive bioelectrochemical sensor: Optimized meloxicam detection using CCD-RSM design and application for human plasma sample.

Ultrasonics sonochemistry Bahrani S, Razmi Z, Ghaedi M, Asfaram A, Javadian H
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

In this research, gold nanoparticles modified choline chloride functionalized graphene oxide (AuNPs-ChCl-GO) was synthesized through the assistance of ultrasound and fabricated as a novel bioelectrochemical sensor and utilized for the sensitive detection of meloxicam (MEL). The morphological and structural features of the AuNPs-ChCl-GO were characterized using different techniques including FTIR, TEM, FE-SEM, EDX, and XRD. The modified electrode showed a remarkable improvement in the anodic oxidation activity of MEL due to the enhancement in the current response compared to the bare carbon paste electrode (CPE). The biosensor composition and measurement conditions were optimized using an experimental design. The differential pulse voltammetry (DPVs) exhibited expanded linear dynamic in the range of 9.0 × 10-9 to 8.5 × 10-7 M for MEL in Britton-Robinson buffer at pH = 4.0 with a detection limit of 1.008 × 10-9 M. The practical utility of the modified electrode was demonstrated by the accurate detection of MEL in human plasma sample.

关键词