2018

Fabrication of a promising immobilization platform based on electrochemical synthesis of a conjugated polymer.

Colloids and surfaces. B, Biointerfaces Buber E, Soylemez S, Udum YA, Toppare L
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Since conjugated polymers are an important class of materials with remarkable properties in biosensor applications, in this study, a novel glucose biosensor based on a conjugated polymer was fabricated via the electropolymerization of the monomer 10,13-bis(4-hexylthiophen-2-yl)dipyridol[3,2-a:2',3'-c]phenazine onto a graphite electrode surface. Glucose oxidase (GOx) was used as the model biological recognition element. As a result of the enzymatic reaction between GOx and glucose, the glucose amount was determined by monitoring the change in the oxygen level associated with substrate concentration via the amperometric detection technique. The proposed system possessed superior properties with KMapp value of 0.262 mM, 2.88 × 10-3 mM limit of detection and 105.12 μA mM-1 cm-2 sensitivity. These results show that conjugated polymer film provides an effective and stable immobilization matrix for the enzyme. Finally, the biosensor was applied successfully to several commercially available beverage samples for glucose determination proving an inexpensive and highly sensitive system applicable for real time analyses.

关键词