2018

Monitoring dynamic release of intracellular hydrogen peroxide through a microelectrode based enzymatic biosensor.

Analytical and bioanalytical chemistry Zhang H, Ruan J, Liu W, Jiang X, Du T, Jiang H, Alberto P, Gottschalk KE, Wang X
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A high sensitive and selective hydrogen peroxide (H2O2) biosensor was fabricated on the basis of reduced hemoglobin (Hb) and single-walled carbon nanotubes (SWCNTs) for detecting the release of H2O2 from living HepG2 cancer cells in the process of the in situ biosynthesis of ZnO quantum. The modification of carbon fiber microelectrode (CFME) was carried out by physical adsorption. By the scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), the dense cover of surface and successful immobilization were characterized. Electrochemical investigation demonstrates that the as-prepared modified microelectrode showed a quasi-reversible process toward the reduction of H2O2, which exhibited a linear range from 0.51 to 10.6 μM, with a limit of detection of 0.23 μM. This microelectrode biosensor was applied for the quantification of the change of H2O2 concentration released from HepG2 cells through the in situ biosynthesis of ZnO quantum dots, which was further confirmed by the fluorescence staining.

关键词