2018

Detection of Bisphenol A Using DNA-Functionalized Graphene Field Effect Transistors Integrated in Microfluidic Systems.

ACS applied materials & interfaces Liu S, Fu Y, Xiong C, Liu Z, Zheng L, Yan F
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Bisphenol A (BPA) detection has attracted much attention recently for its importance to food safety and environment. The DNA-functionalized solution-gated graphene transistors are integrated in microfluidic systems and used for recycling detections of BPA for the first time. In the presence of BPA, both single- and double-stranded DNA molecules are detached and released from the graphene surface in aqueous solutions, leading to the change of device electrical performance. The channel currents of the devices change monotonically with the concentration of BPA. Moreover, the devices modified with double-stranded DNA are more sensitive to BPA and show the detection limit down to 10 ng/mL. The highly sensitive label-free BPA sensors are expected to be used for convenient BPA detections in many applications.

关键词