2018

High-performance electrochemical biosensor for nonenzymatic H

Biosensors & bioelectronics Dai H, Chen Y, Niu X, Pan C, Chen H, Chen X
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

An ingenious and viable method for preparing heterogeneous Co3O4 dodecahedrons that contain carbon and encapsulated Au nanoparticles (Au@C-Co3O4) was proposed via pyrolysis of Au nanoparticle-encapsulated zeolitic imidazolate framework-67 (Au@ZIF-67). The obtained Au@C-Co3O4 possessed hierarchically porous structure, abundant active sites, excellent conductivity, and durability, all of which can significantly improve the analysis performance of the biosensor. Meanwhile, the fabricated electrode based on the porous Au@C-Co3O4 showed remarkable electrocatalytic performance towards H2O2 with a limit of detection of 19 nM and ultra-high sensitivity of 7553 μA mM-1 cm-2, even when the Au content in the composite was as low as 0.85 wt%. This novel biosensor was successfully used to monitor H2O2 concentration released from living cells, and the results can be used to identify cancer cells, thus advancing the use of transition metal oxides in the field of biosensing.

关键词