A Fluorescent Carbon Nanotube Sensor Detects the Metastatic Prostate Cancer Biomarker uPA.

ACS sensors Williams RM, Lee C, Heller DA
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Therapeutic outcomes in patients with prostate cancer are hindered by the inability to discern indolent versus aggressive disease. To address this problem, we developed a quantitative fluorescent nanosensor for the cancer biomarker urokinase plasminogen activator (uPA). We used the unique fluorescent characteristics of single-walled carbon nanotubes (SWCNT) to engineer an optical sensor that responds to uPA via optical bandgap modulation in complex protein environments. The sensing characteristics of this construct were modulated by passivation of the hydrophobic SWCNT surface with bovine serum albumin (BSA). The sensor enabled quantitative detection of known uPA concentrations in human blood products. These experiments potentiate future use of this technology as a rapid, point-of-care sensor for biomarker measurements in patient fluid samples. We expect that further work will develop a method to discern aggressive vs indolent prostate cancer and reduce overtreatment of this disease.

关键词