2019

An electrochemical biosensor based on hemoglobin-oligonucleotides-modified electrode for detection of acrylamide in potato fries.

Food chemistry Asnaashari M, Kenari RE, Farahmandfar R, Abnous K, Taghdisi SM
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Acrylamide a neurotoxin and strong carcinogen, is found in various thermally processed foods. In this study, an electrochemical sensor for detection of acrylamide using double stranded DNA (dsDNA)/Hemoglobin (Hb)-modified screen printed gold electrode (SPGE) was designed. The immobilization of ssDNA1-SH on the surface of SPGE was confirmed by cyclic voltammetry, and the interaction between ssDNA2-NH2 and Hb with the ratio 1:1 was characterized by agarose gel. The excellent response of the designed biosensor towards acrylamide due to acrylamide and Hb adducts and change of reduction/oxidation process of Hb-Fe(III)/Hb-Fe(II) was determined by square wave voltammetry (SWV). The biosensor showed the optimum response at pH 8.0. The linear working range for acrylamide was from 2.0 × 10-6 to 5.0 × 10-2 M with a detection limit of 1.58 × 10-7 M. The biosensor was suitable for direct determination of acrylamide in water extracted of potato fries and displayed good reproductivity and high stability.

关键词