组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
In this study, we constructed a new and sensitive ITO based electrochemical immunosensor for detection of interleukin 1β (IL-1β), a cancer biomarker found in serum and saliva. 6-phosphonohexanoic acid (PHA) was used as a biomolecule immobilization matrix for the first time. Anti-IL-1β antibody was utilized as a biorecognition molecule that immobilized onto carboxyl groups of 6-phosphohexanoic acid (PHA) via amide bond. Selective interaction between anti- IL-1β antibodies and IL-1β antigens was investigated by Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV) and Single Frequency Impedance (SFI) methods. The surface characterization of the immunosensor was performed by fourier transform infrared spectroscopy (FTIR), raman spectroscopy, scanning electron microscopy (SEM), SEM-energy dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM) in order to illustrate individual steps of biosensor construction. Under the optimized experimental conditions, the change in impedance was proportional to IL-1β concentrations in the range of 0.025-3 pg/mL (R2 = 0.99) with detection limit of 7.5 fg/mL. The reproducibility, repeatability, stability, and specificity of the developed immunosensor were analyzed. In addition, the developed immunosensor was successfully utilized for the determination of IL-1β in serum and saliva samples by using the standard addition method with recoveries of 96.7-105.4%. This immunosensor was applicable for the requirements of routine analysis with respect to performance, functionality and cost.