2018

Long segment detection of HTLV-1 genome based on the fluorescence quenching technique.

Heliyon Ghobadi MZ, Mozhgani SH, Hakimian F, Norouzi M, Rezaee SA, Ghourchian H
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Detecting fluorescence changes due to energy transfer between a quencher and fluorophore is a common method used for the fluorescence-based biosensors. In the present report, a new biosensor for long segment detection of the human T cell-lymphotropic virus 1 genome was constructed based on the fluorescence quenching of graphene oxide by gold nanoparticles. The fluorescence signal of unmodified graphene oxide was measured before and after hybridization of target and probes functionalized with gold nanoparticles. The limit of detection of the biosensor was determined to be around 10 pg/mL. The specific design for long segment of target assures the selectivity of biosensor. Our results proposed that further development may be useful to detect other viruses.

关键词