2019

Design of an Integrated Optics Sensor Structure Based on Diamond Waveguide for Hemoglobin Property Detection.

Materials (Basel, Switzerland) Struk P
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

This manuscript presents a theoretical analysis of a diamond-based integrated optics structure for applications in biosensors. The geometrical, optical, and sensitivity properties of an integrated optical structure were theoretically analyzed and optimized for biosensor applications. The analysis focused on determining the waveguide properties, including the effective refractive index Neff as a function of refractive index nw and thickness dw of waveguide layer, refractive index of the hemoglobin cover layer ncH and substrate layer ns, homogeneous sensitivity dNeff/dncH, and modal field distribution of guided waveguide modes. The analysis was completed for two types of waveguide layer materials: undoped or boron-doped diamond films with or without the hemoglobin cover layer. The presented experimental results form a base for developing biosensor structures based on integrated optics for determining the properties of hemoglobin.

关键词