We report an amperometric biosensor for the urinary disease biomarker para-hydroxyphenylacetate ( p-HPA) in which the allosteric reductase component of a bacterial hydroxylase, C1-hpah, is electrically wired to glassy carbon electrodes through incorporation into a low-potential Os-complex modified redox polymer. The proposed biosensing strategy depends on allosteric modulation of C1-hpah by the binding of the enzyme activator and analyte p-HPA, stimulating oxidation of the cofactor NADH. The pronounced concentration-dependence of allosteric C1-hpah modulation in the presence of a constant concentration of NADH allowed sensitive quantification of the target, p-HPA. The specific design of the immobilizing redox polymer with suitably low working potential allowed biosensor operation without the risk of co-oxidation of potentially interfering substances, such as uric acid or ascorbic acid. Optimized sensors were successfully applied for p-HPA determination in artificial urine, with good recovery rates and reproducibility and sub-micromolar detection limits. The proposed application of the allosteric enzyme C1-hpah for p-HPA trace electroanalysis is the first successful example of simple amperometric redox enzyme/redox polymer biosensing in which the analyte acts as an effector, modulating the activity of an immobilized biocatalyst. A general advantage of the concept of allosterically modulated biosensing is its ability to broaden the range of approachable analytes, through the move from substrate to effector detection.