组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
The fast and accurate real-time monitoring of hydrogen peroxide (H2O2) secreted from living cells plays a critical role in clinical diagnosis and management. Herein, we report low-cost and self-supported MoS2 nanosheet arrays for non-enzymatic eletrochemical H2O2 detection. Under the optimal test conditions, such MoS2 electrodes exhibit extremely promising electrocatalytic performance with a low detection limit of 1.0 μM (S/N = 3) and an excellent sensitivity of 5.3 mA mM-1 cm-2. Furthermore, the detection of the trace amount of H2O2 secreted from live A549 cancer cells was successfully performed with this biosensor.