2019

Ex vivo perfusion-based engraftment of genetically engineered cell sensors into transplantable organs.

PloS one Chin LY, Carroll C, Raigani S, Detelich DM, Tessier SN, Wojtkiewicz GR, Schmidt SP, Weissleder R, Yeh H, Uygun K, Parekkadan B
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Cellular rejection of liver transplant allografts remains a concern despite immunosuppressant use. Existing transplant biomarkers are often not sensitive enough to detect acute or chronic rejection at an early enough stage to allow successful clinical intervention. We herein developed a cell-based sensor that can potentially be used for monitoring local events following liver transplantation. Utilizing a machine perfusion system as a platform to engraft the cells into a donor liver, we effectively established the biocompatibility of the biosensor cells and confirmed efficient delivery of cells distributed throughout the organ. This work proves an innovative concept of integrating synthetic reporter cells ex vivo into organs as a transplant-within-a-transplant during functional organ preservation with a vision to use cell biosensors as a broad way to monitor and treat tissue transplants.

关键词