组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
BACKGROUND: Urinary tract infection (UTI) is the most common bacterial infection in the world. Some cases can have serious complication as death by septic shock. With the increasing spread of multidrug-resistant bacteria, the therapeutic possibilities against the complicated UTI are exhausted, forcing the use of broad-spectrum antibiotics such as meropenem.
OBJECTIVES: To evaluate the penetrating ability of meropenem to renal tissue using an enzymatic biosensor in samples of renal cortex and its correlation with plasma levels.
METHOD: We conducted a descriptive study in humans with indication of kidney biopsy. Meropenem was administered 1 hour before performing the biopsy, and the concentrations of meropenem in a series of samples of plasma and renal biopsy were determined.
RESULTS: Renal biopsy and plasma samples of 14 patients, 64% women with body mass index of 26.3 kg/m2 (SD ± 2.9) and estimated glomerular filtration rate of 57.5 mL/min/1.73 m2 (SD ± 44.1), were examined. Renal biopsy was done at 68.9 minutes (SD ± 20.3), and the second plasma sample was obtained at 82.1 minutes (SD ± 21.2) and the third at 149.6 minutes (SD ± 31.5). The mean kidney meropenem concentration was 3.1 μg/mL (SD ± 1.9). For each patient, a decay curve of plasma meropenem concentration was constructed. The proportion of meropenem concentrations in renal tissue and plasma at biopsy moment was 14% (SD ± 10) with an interquartile range of 5.5-20.3%. With normal renal function, meropenem can achieve a bactericidal effect towards bacteria with MIC-90 < 0.76 μg/mL in the renal parenchyma.
CONCLUSIONS: Meropenem is effective to treat the most frequent uropathogens with the bactericidal effect. Nevertheless, for resistant bacteria, it is necessary to adjust the dose to achieve adequate parenchymal concentration.