2020

Use of bacterial cellulose film modified by polypyrrole/TiO

Carbohydrate polymers Ghasemi S, Bari MR, Pirsa S, Amiri S
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The aim of this study was to use of bacterial cellulose/polypyrrole/TiO2-Ag (BC/PPy/TiO2-Ag) nanocomposite film to detect and measure the growth of 5 pathogenic bacteria. For this purpose, at first, 13 BC/PPy/TiO2-Ag films were fabricated, then bacterial suspensions were prepared according to McFarland standard. The results showed that by increasing the bacterial concentration, the electrical resistance of sensors was decreased and there was a relation between bacterial concentration and bacterial type with electrical resistance change of sensors. The obtained data showed that the sensitivity of the sensors was increased with increasing the concentration of polypyrrole and TiO2-Ag. FT-IR and SEM tests were performed to investigate the interaction between nanoparticles and determine the size of nanoparticles. The BC/PPy/TiO2-Ag biosensors are portable and the response time of these sensors is very short for target analysis. Therefore, these sensors have the potential to improve biological safety as diagnostic tools.

关键词