Surface plasmon resonance based biomimetic sensor for urinary tract infections.

Talanta Özgür E, Topçu AA, Yılmaz E, Denizli A
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Tailor-made Escherichia coli (E. coli) receptors were created with microcontact imprinted technique and binding events of E. coli were carried out by a surface plasmon resonance (SPR) sensor in aqueous solution and in urine mimic in real time and label-free. N-methacryloyl-(l)-histidine methyl ester (MAH) was selected as a functional monomer to design tailor-made E. coli receptors on the polymeric film and during the formation of the polymeric film on a chip surface, Ag nanoparticles (AgNPs) were entrapped into the polymer mixture in order to lower the detection limit of biomimetic SPR based sensor. The polymeric film was characterized with atomic force microscopy (AFM), scanning electron microscopy (SEM), ellipsometer and contact angle measurements. Limit of detection (LOD) was found 0.57 CFU/mL and feasibility of the biomimetic sensor was investigated in urine mimic.