2020

A liquid-crystal-based immunosensor for the detection of cardiac troponin I.

The Analyst Xia C, Zhou D, Su Y, Zhou G, Yao L, Sun W, Liu Y
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Cardiac troponin I (cTnI) is one of the most sensitive and specific markers of myocardial cell injury, which can detect even minor myocardial damages. It is recognized as the main biochemical marker of the rapid diagnosis of acute myocardial infarction (AMI) and acute coronary syndrome (ACS). In this study, a label-free biosensor that utilizes the birefringence property of a nematic liquid crystal (LC) for the detection of cTnI is demonstrated. A chemically sensitive film with specific molecular recognition ability was decorated on the surface of a substrate, and the LC molecules were arranged in a vertically oriented order under the influence of the sensitive film, and a dark background signal was obtained using a polarizing optical microscope. When the antigen-antibody specifically binds to form a stronger acting force, the orientation of the LC molecules changes, resulting in a bright optical appearance. This LC-based immunosensor not only has the advantages of a facile structure, low cost and excellent specificity but also high sensitivity (a low detection limit of 1 pg ml-1), and has a promising future in biomedical related fields.