2020

Picomolar-level detection of mercury within non-biological/biological aqueous media using ultra-sensitive polyaniline-Fe

Analytical and bioanalytical chemistry Hashemi SA, Mousavi SM, Bahrani S, Ramakrishna S, Hashemi SH
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Mercury as the 3rd most toxic, non-biodegradable, and carcinogenic pollutant can adversely affect the ecosystem and health of living species through its bioaccumulation within the nature that can affect the top consumer in the food chain; therefore, it is vital to sense/remove Hg2+ within/from aqueous media using practical approaches. To address this matter, we modified the glassy carbon electrode (GCE) with ultra-sensitive, interconnected, sulfurized, and porous nanostructure consisted of polyaniline-Fe3O4-silver diethyldithiocarbamate (PANi-F-S) to enhance the sensitivity, selectivity, and limit of detection (LOD) of the sensor. Obtained results showed that at optimum conditions (i.e., pH value of 7, deposition potential of - 0.8 V, and accumulation time of 120 s), for Hg2+ concentration ranging from 0.4 to 60 nM, the modified electrode showing linear relative coefficient of 0.9983, LOD of 0.051 nM, LOQ of 0.14 nM, and sensitivity of 1618.86 μA μM-1 cm-2 highlights superior sensitivity of the developed platform until picomolar level. Additionally, the modified electrode showed ideal repeatability, stability, reproducibility, and selectivity (by considering Zn2+, Cd2+ Pb2+, Cu2+, Ni2+, and Co2+ as metal interferences) and recovered more than 99% of the Hg2+ ions within non-biological (mineral, tap, and industrial waters) and biological (blood plasma sample) fluids. Graphical abstract.

关键词