组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
As optical reporting elements, fluorescent proteins are extensively used in whole-cell microbial biosensors. However, the use of these optical reporters is limited in opaque media such as soil. This study described a method utilizing gas as a reporting signal that could be used for the rapid on-site detection of mercury in soil. In this biosensor, the MerR protein could capture mercury ions and then bind the promoter of the efe gene to initiate the synthesis of the ethylene (C2H4)-forming enzyme that produced the gas. The research showed that the mercury ion concentrations could be converted into C2H4 gas signals, which were quantified using a handheld C2H4 sensor. By optimizing the biosensor to improve its anti-interference ability in the system, it could detect mercury ion concentrations in the soil ranging from 0.2 to 20 mg/kg within 45 min, effectively reflecting whether the mercury pollution in the soil exceeded the limit standard. This study provides a simple, inexpensive, and portable method for the on-site detection of soil pollutants.