Hydrogen Peroxide Detection by Super-Porous Hybrid CuO/Pt NP Platform: Improved Sensitivity and Selectivity.

Nanomaterials (Basel, Switzerland) Kulkarni R, Kunwar S, Mandavkar R, Jeong JH, Lee J
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A super-porous hybrid platform can offer significantly increased number of reaction sites for the analytes and thus can offer advantages in the biosensor applications. In this work, a significantly improved sensitivity and selectivity of hydrogen peroxide (H2O2) detection is demonstrated by a super-porous hybrid CuO/Pt nanoparticle (NP) platform on Si substrate as the first demonstration. The super-porous hybrid platform is fabricated by a physiochemical approach combining the physical vapor deposition of Pt NPs and electrochemical deposition of super-porous CuO structures by adopting a dynamic hydrogen bubble technique. Under an optimized condition, the hybrid CuO/Pt biosensor demonstrates a very high sensitivity of 2205 µA/mM·cm2 and a low limit of detection (LOD) of 140 nM with a wide detection range of H2O2. This is meaningfully improved performance as compared to the previously reported CuO-based H2O2 sensors as well as to the other metal oxide-based H2O2 sensors. The hybrid CuO/Pt platform exhibits an excellent selectivity against other interfering molecules such as glucose, fructose, dopamine, sodium chloride and ascorbic acid. Due to the synergetic effect of highly porous CuO structures and underlying Pt NPs, the CuO/Pt architecture offers extremely abundant active sites for the H2O2 reduction and electron transfer pathways.