组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
OBJECTIVE: To develop a convenient and efficient means for organophosphate (OP) insecticide detection, a simple, cost-effective, and easy-to-use absorbance-based sensing device was generated using methyl parathion hydrolase fused with glutathione-S-transferase (MPH-GST) covalently immobilized onto a chitosan film-coated microplate.
RESULTS: With methyl parathion (MP) as a representative substrate, this MPH-GST sensing microplate had the detection limit of 0.1 µM and the linear range of 0.1-50 µM. Despite its highest stability at 4 °C, it was considerably stable at 25 °C with high activity for 30 days. It was also most stable at pH 8.0 and could be efficiently reused up to 100 rounds. The device revealed a high percentage of recovery for tap water spiked with a known concentration of MP, which was also comparable to the result obtained from gas chromatography-mass spectrometry. It also showed a high recovery of 82-100% with MP spiked agricultural products and satisfactory results with non-spiked samples. This immobilized enzyme sensing system was more sensitive and efficient than the whole cell system from our previous work.
CONCLUSIONS: All of the advantages of the MPH-GST sensing microplate developed have rendered it suitable for rapid and convenient OP screening, and for being a bio-element for fabricating a potential optical biosensor in the future.