2021

Biosensor Based on In₂O₂ Electrolyte Gated Thin Film Transistor With Integrated On-Chip Gate Electrode.

IEEE transactions on nanobioscience Yang P, Rong H, Wu Z, Pei Y
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

In this work, In2O3 electrolyte gated thin film transistors (In2O3-EGTFTs) with integrated on-chip gate electrode were investigated as a label-free biosensor. The In2O3 channel works as sensitive membrane and the on-chip gate electrode replaces reference electrode. The pH sensitivity of the device is 64 mV/pH with the deviation of 10 mV. The In2O3 channel was coated by streptavidin/neutravidin receptors to detect the target biomolecules of biotin. The streptavidin modified device presents an ultra-low working voltage ( [Formula: see text] V, [Formula: see text] mV) and the detection limit as low as 50 pg · mL -1 . And the neutravidin modified device presents apparent detecting performance even in low biotin concentration of 50 fg · mL -1 under a working voltage of [Formula: see text] V and [Formula: see text] mV. This work provides a high-performance biosensor device with low power consumption and simple structure that is easy to integrate and package.

关键词