组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
In this work, In2O3 electrolyte gated thin film transistors (In2O3-EGTFTs) with integrated on-chip gate electrode were investigated as a label-free biosensor. The In2O3 channel works as sensitive membrane and the on-chip gate electrode replaces reference electrode. The pH sensitivity of the device is 64 mV/pH with the deviation of 10 mV. The In2O3 channel was coated by streptavidin/neutravidin receptors to detect the target biomolecules of biotin. The streptavidin modified device presents an ultra-low working voltage ( [Formula: see text] V, [Formula: see text] mV) and the detection limit as low as 50 pg · mL -1 . And the neutravidin modified device presents apparent detecting performance even in low biotin concentration of 50 fg · mL -1 under a working voltage of [Formula: see text] V and [Formula: see text] mV. This work provides a high-performance biosensor device with low power consumption and simple structure that is easy to integrate and package.