2021

A single quantum dot-based fluorescence resonance energy transfer biosensor for antibody-free detection of ten-eleven translocation 1.

Chemical communications (Cambridge, England) Hu J, Yao J, Wang J, Pan LY, Qiu JG, Zhang CY
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

We developed a single quantum dot-based fluorescence resonance energy transfer biosensor for antibody-free detection of ten-eleven translocation 1 (TET1). This biosensor can sensitively detect TET1 in a homogeneous manner without the involvement of any specific antibodies, and it can be used for accurate measurement of TET1 activity in human neuroblastoma cells and the screening of TET1 inhibitors.

关键词