2021

Colorimetric and Electrochemical Dual-Signal Method for Water Toxicity Detection Based on

ACS sensors Yu D, Li R, Sun X, Zhang H, Yu H, Dong S
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The development of simple and rapid toxicity detection methods has important practical significance. In this work, a dual-signal method with colorimetric and electrochemical properties for water toxicity detection was proposed for the first time based on a rapid color reaction between Escherichia coli (E. coli) and p-benzoquinone (BQ). Here, E. coli was used as a biocatalyst and BQ was used as a mediator. An IC50 value of 0.75 mg L-1 for Cu2+ was obtained using a two-step electrochemical detection method. Strikingly, toxicity could also be estimated visually by the naked eye, and the minimum detection limit was 3.2 mg L-1 for Cu2+. The dual-signal toxicity detection method extends the function of BQ, and the result is more reliable than the traditional single-signal method. This simple and rapid toxicity detection method shows certain application prospects.