2021

Well-orientation strategy for direct binding of antibodies: Development of the immunochromatographic test using the antigen modified Fe

Food chemistry He K, Bu T, Zhao S, Bai F, Zhang M, Tian Y, Sun X, Dong M, Wang L
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

One of the major concerns in the application of nanocarriers in biosensing is the impair of the recognition molecules bioactivity loaded on their surfaces due to harsh and laborious cross-linking and random orientation, resulting in unsatisfactory sensitivity. Herein, we proposed a novel immunochromatographic test strip (FNS-ag-DICTS) by taking advantage of the antigen (ag) modified Fe2O3 nanostructures (FNSs) as new signal tags and goat anti-mouse IgG labeling on the detection line instead of ag, which was used for sensitive detection of aflatoxin B1 (AFB1). The fabricated FNS-ag can orientate the Fab region of monoclonal antibodies (mAbs), waiving the intrinsic limitations of traditional nanomaterials labeled mAbs. Under optimal conditions, FNS-ag-DICTS possessed excellent specificity and a wide detection range, with a visual limit of detection (vLOD) of 0.0125 ng mL-1. In addition, the biosensor successfully detected AFB1 in peanut, green bean and corn, with an average recovery rate of 82.8-124.9%.

关键词