2021

Performance of a dual-chamber microbial fuel cell as biosensor for on-line measuring ammonium nitrogen in synthetic municipal wastewater.

The Science of the total environment Do MH, Ngo HH, Guo W, Chang SW, Nguyen DD, Sharma P, Pandey A, Bui XT, Zhang X
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

This study investigates the performance of microbial fuel cells (MFC) for on-line monitoring ammonium (NH4+-N) in municipal wastewater. A double chamber microbial fuel cell (MFC) was established in a continuous mode under different influent ammonium concentrations ranging from 5 to 40 mg L-1. Results indicated that excess ammonium would inhibit the activity of electrogenic bacteria in the anode chamber and consequently affect electricity production. An inversely linear relationship between concentration and voltage generation was obtained with coefficient R2 0.99 and the MFC could detect up to 40 mg L-1 of NH4+-N. Notably, no further decline was observed in voltage output and there was in fact a further increase in ammonia concentration (>40 mg L-1). The stability and high accuracy of ammonium-based MFC biosensors exposed competitive results compared to traditional analytical tools, confirming the biosensor's reliability. Furthermore, pH 7.0; R 1000 Ω and HRT of 24 h are the best possible conditions for the MFC biosensor for monitoring ammonium. The simplicity in design and operation makes the biosensor more realistic for practical application.

关键词