组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
Chemiluminescent (CL) reaction between hydrogen peroxide (H2O2) and luminol was dramatically enhanced by sodium molybdate (Na2MoO4) for 284-fold. CL mechanism investigation indicated that Na2MoO4 increased the production of hydroxyl radical (•OH) and superoxide anion (•O2-) in the H2O2-luminol system, which could attribute to the enhanced-CL intensity and gave us new insights into the CL-enhanced property of Na2MoO4. The CL intensity of Na2MoO4-H2O2-luminol system increased with the concentration of H2O2, based on which, a convenient and sensitive CL determination method could be developed for H2O2 in the concentration ranging from 0.5 to 60 μmol/L, with a detection limit of 0.25 μmol/L. Combining with glucose oxidase, the Na2MoO4-H2O2-luminol system could also be applied for glucose detection. Glucose in human serum has been successfully detected with satisfied recoveries in the range of 96.7 % to 105.4 %.