2022

Lab-In-A-Syringe: A Novel Electrochemical Biosensor for On-Site and Real-Time Monitoring of Dopamine in Freely Behaving Mice.

ACS sensors Alachkar A, Alhassan S, Senel M
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

There is a growing demand for real-time analysis and sampling of biofluids on a single low-cost platform in ultralow fluid volumes with robustness. In this study, a microfluidic sensor was developed, manufactured through an additive manufacturing technique, and used for dopamine (DA) measurements. We implemented a biosensing system using pencil graphites (PGEs) integrated into a three-dimensional (3D) printed microfluidic syringe-type device (μSyringe). The amperometry technique was used to monitor the current changes associated with the electrooxidation of DA. The sensing signal was stable and linear in a concentration range of DA between the limit of quantification (0.1 nM) and the upper limit of linearity (500 nM). The μSyringe sensing device is simple, robust, and stable, making it suitable for real-time measurement of DA in cerebrospinal fluid (CSF) from freely moving mice.

关键词