2020

Simultaneous Determination of l-Phenylalanine, Phenylethylamine, and Phenylacetic Acid Using Three-Color Whole-Cell Biosensors within a Microchannel Device.

ACS applied bio materials Hsu LW, Lin YH, Guo JY, Chen CF, Chou YJ, Yeh YC
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The neurotransmitter phenylethylamine (PEA) is highly susceptible to oxidation to produce phenylacetic acid (PA). The fact that PEA and PA are both metabolites of phenylalanine (Phe) in humans makes them important indicators in the diagnosis of phenylketonuria. In this work, three-color whole-cell biosensors were developed to simultaneously detect these analytes (Phe, PEA, and PA). The tyrosine-responsive promoter was used to control the production of green fluorescent protein signals in response to Phe levels. The FeaR regulon was first used to indicate the presence of PEA, whereas the Paa regulon was used for the detection of PA. The combination of three sensor strains together made it possible to semiquantify the three analytes according to unique color outputs without cross-interference. We sought to optimize various modular components (ribosomal binding sites and fluorescent proteins) to ensure the rapid generation of fluorescent signals. Finally, the biosensors were implemented within a microchannel device to reduce sample consumption in point-of-care assays.

关键词