2022

Refractive index sensor with magnified resonant signal.

Scientific reports Zaky ZA, Alamri S, Zhaketov VD, Aly AH
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Herein, we theoretically suggest one-dimensional photonic crystal composed of polymer doped with quantum dots and porous silicon. The present simulated design is proposed as a refractive index biosensor structure based on parity-time symmetry. Under the parity-time conditions, the transmittance of the resonant peaks is magnified to be 57,843% for refractive index 1.350, 2725% for 1.390, 2117% for 1.392, 1502% for 1.395, 1011% for 1.399, and 847% for 1.401. By magnification, we can distinguish between different refractive indices. The present design can record an efficiency twice the published designs as clear in the comparison table. Results clear that the sensitivities are 635 nm/RIU and 1,000,000%/RIU. So, it can be used for a broader range of detection purposes.

关键词