2022

Optical Anisotropy and Excitons in MoS

Biosensors Eghbali A, Vyshnevyy AA, Arsenin AV, Volkov VS
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The use of ultra-thin spacer layers above metal has become a popular approach to the enhancement of optical sensitivity and immobilization efficiency of label-free SPR sensors. At the same time, the giant optical anisotropy inherent to transition metal dichalcogenides may significantly affect characteristics of the studied sensors. Here, we present a systematic study of the optical sensitivity of an SPR biosensor platform with auxiliary layers of MoS2. By performing the analysis in a broad spectral range, we reveal the effect of exciton-driven dielectric response of MoS2 and its anisotropy on the sensitivity characteristics. The excitons are responsible for the decrease in the optimal thickness of MoS2. Furthermore, despite the anisotropy being at record height, it affects the sensitivity only slightly, although the effect becomes stronger in the near-infrared spectral range, where it may lead to considerable change in the optimal design of the biosensor.

关键词