An amperometric immunosensor was developed for the analysis of the major egg-white allergen ovotransferrin (Gal d 3) in commercial food products because the (accidental) intake, skin contact with, and/or inhalation of eggs can lead to severe disorders in allergic individuals. Employing a sandwich-type immunosensing strategy, screen-printed carbon electrodes (SPCE) were biomodified with anti-Gal d 3 (capture) antibodies, and the allergen’s detection was achieved with anti-Gal d 3 antibodies labelled with horseradish peroxidase (HRP). The 3,3′,5,5′-tetramethylbenzidine (TMB)/H2O2 reaction with HRP was used to obtain the electrochemical (amperometric) signal. An attractive assay time of 30 min and a remarkable analytical performance was achieved. The quantification range was established between 55 and 1000 ng·mL−1, with a limit of detection of 16 ng·mL−1. The developed method demonstrated good precision (Vx0 = 5.5%) and provided precise results (CV < 6%). The sensor also detected extremely low amounts (down to 0.010%) of egg. The analysis of seven raw and/or cooked egg and egg-white samples indicated that food processing influences the amount of allergen. Furthermore, to assure the compliance of product labelling with EU legislation, 25 commercial food ingredients/products were analysed. The accuracy of the results was confirmed through an ELISA assay. The stability of the ready-to-use sensing surface for 20 days allows a reduction of the reagents’ volumes and cost.