2023

Porous nitrogen-doped reduced graphene oxide-supported CuO@Cu

iScience Wei Q, Wu L, Zhu M, Wang Z, Huang ZH, Wang MX
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Constructing high-performance enzyme-free biosensors for detecting glucose is essential to preliminary diabetes diagnosis. Here, copper oxide nanoparticles (CuO@Cu2O NPs) were anchored in porous nitrogen-doped reduced graphene oxide (PNrGO) to construct CuO@Cu2O/PNrGO/GCE hybrid electrode for sensitive detection of glucose. Benefiting from the remarkable synergistic effects between the multiple high activation sites of CuO@Cu2O NPs and the dramatic properties of PNrGO with excellent conductivity and large surface area with many accessible pores, the hybrid electrode possesses outstanding glucose sensing performance that is far superior to those of pristine CuO@Cu2O electrode. The as-fabricated enzyme-free glucose biosensor displays prominent glucose sensitivity of 2,906.07 μA mM-1 cm-2, extremely low limit of detection of 0.13 μM, and wide linear detection of 3 μM-6.772 mM. In addition, excellent reproducibility, favorable long-term stability, and distinguished selectivity are obtained in the glucose detection. Importantly, this study provides promising results for continuous improvement of non-enzyme sensing applications.

关键词