2023

Systematic Mutation and Unnatural Base Pair Incorporation Improves Riboswitch-Based Biosensor Response Time.

ACS sensors Manna S, Kimoto M, Truong J, Bommisetti P, Peitz A, Hirao I, Hammond MC
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Engineered RNAs have applications in diverse fields from biomedical to environmental. In many cases, the folding of the RNA is critical to its function. Here we describe a strategy to improve the response time of a riboswitch-based fluorescent biosensor. Systematic mutagenesis was performed to either make transpose or transition base pair mutants or introduce orthogonal base pairs. Both natural and unnatural base pair mutants were found to improve the biosensor response time without compromising fold turn-on or ligand affinity. These strategies can be transferred to improve the performance of other RNA-based tools.

关键词