2024

Dual-Mode Graphene Field-Effect Transistor Biosensor with Isothermal Nucleic Acid Amplification.

Biosensors Kim HE, Schuck A, Park H, Chung DR, Kang M, Kim YS
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Despite a substantial increase in testing facilities during the pandemic, access remains a major obstacle, particularly in low-resource and remote areas. This constraint emphasizes the need for high-throughput potential point-of-care diagnostic tools in environments with limited resources. Loop-mediated isothermal amplification (LAMP) is a promising technique, but improvements in sensitivity are needed for accurate detection, especially in scenarios where the virus is present in low quantities. To achieve this objective, we present a highly sensitive detection approach of a dual-mode graphene-based field-effect transistor (G-FET) biosensor with LAMP. The G-FET biosensor, which has a transparent graphene microelectrode array on a glass substrate, detects LAMP products in less than 30 min using both observable color changes and Dirac point voltage measurements, even in samples with low viral concentrations. This dual-mode G-FET biosensor emerges as a potential alternative to conventional RT-PCR for severe acute respiratory syndrome-associated coronavirus (SARS-CoV)-2 detection or point-of-care testing, particularly in resource-constrained scenarios such as developing countries. Moreover, its capacity for colorimetric detection with the naked eye enhances its applicability in diverse settings.

关键词