2025

Design and validation of ultra-compact metamaterial-based biosensor for non-invasive cervical cancer diagnosis in terahertz regime.

PloS one Hamza MN, Tariqul Islam M, Lavadiya S, Ud Din I, Sanches B, Koziel S, Islam MS
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Cervical cancer belongs to the most dangerous types of cancers posing considerable threat to women's survival. It is most often diagnosed in the advanced stages as precancerous lesions are often symptom-free and difficult to identify. Microwave imaging, especially in terahertz (THz) range, is a convenient and noninvasive cancer detection tool. It enables characterization of biological tissues and discrimination between healthy and malignant ones. This study presents a novel triple-band biosensor based on metamaterials (MTMs). By leveraging unique properties of MTMs, the proposed biosensor operates as a perfect absorber. It exploits resonant modes in the THz spectrum to achieve remarkable sensitivity. Meticulous selection of the sensor geometry and dimensions enables efficient miniaturization. Meanwhile, utilization of frequency-domain data to detect refractive index changes improves resolution of cancerous tissue identification. Extensive numerical investigations corroborate its ability to carry out reliable early-stage cervical cancer diagnosis. This includes identification of the spatial extent of the malignant tissue. Excellent electrical properties of the sensor are accompanied by its compact size, which is highly desirable for non-invasive and portable applications.