2025

Small but Mighty: A Microfluidic Biofuel Cell-Based Biosensor for the Determination of Ethanol.

Molecules (Basel, Switzerland) Monkratok J, Janphuang P, Chansaenpak K, Lisnund S, Blay V, Pinyou P
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

We developed a membraneless-microfluidic biofuel cell (MBFC) for the quantification of ethanol. The system employs anolyte and catholyte solutions, each containing a biocatalyst and redox mediator. The laminar flow conditions in the microfluidic chip minimize the mixing between anolyte and catholyte and obviate the need for a membrane to separate them. When ethanol is added to the anolyte, alcohol dehydrogenase (ADH) catalyzes its oxidation to acetaldehyde, releasing electrons to the anode. On the cathode, electrons are transferred to horseradish peroxidase (HRP), which reduces hydrogen peroxide in the catholyte to water. We optimized key design factors and operating conditions. We also studied the incorporation of glycerol as a viscosity modifier, which improved the power and current density supplied by the MBFC, with a maximum power output of 307 µW cm-2 and an open circuit voltage of 0.733 V. The proposed ethanol/hydrogen peroxide MBFC was successfully applied as a biofuel cell-based sensor for the quantification of ethanol in a commercial liquor.

关键词