2026

Liquid-Gated Field-Effect Transistor-Based Biosensor for Uric Acid Detection.

Biosensors Ahmad R, Abdullah, Khan A, Husain FM, Lee BI
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Monitoring uric acid (UA) concentration is crucial for human health, enabling early detection and prevention of metabolic disorders as well as assessing renal function and overall metabolic balance. Herein, we developed a field-effect transistor (FET)-based UA biosensor using hydrothermally synthesized vertical zinc oxide (ZnO) nanorods (NRs) and uricase. The fabricated FET biosensor was tested in phosphate-buffered saline (PBS) at increasing UA concentrations to evaluate its biosensing performance. The FET biosensor yields a sensitivity of 12.45 μA·mM-1·cm-2, covering a dynamic range of 0.05-2.75 mM. The calculated detection limit was ~0.0043 mM. The improved sensing performance results in a substantial enhancement of both detection sensitivity and limit of detection compared to the traditional lateral electrode setup. Additionally, selectivity, storage stability, fabrication reproducibility, and applicability for serum UA detection were evaluated. Overall, the vertical electrode configuration of the UA biosensor has the potential to be further extended for the sensitive detection of additional biomarkers.

关键词