2013

A novel colorimetric biosensor for monitoring and detecting acute toxicity in water.

The Analyst Zhai J, Yong D, Li J, Dong S
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

This work presents a new colorimetric microorganism biosensor for monitoring and detecting acute toxicity in water, where prussian blue (PB) is used as the colorimetric indicator and E. coli as the model bacterial. In this biosensor, the electron mediator, ferricyanide, accepts electrons from E. coli during respiration to produce ferrocyanide, which subsequently reacts with ferric ions to yield PB, a famous material with a blue color. Since toxicants can inhibit the respiratory activity of E. coli and then reduce the ferrocyanide and consequent PB production, toxicity can be easily detected by measuring the decrease in the production of PB induced by toxicants. Three important toxicants, 3,5-dichlorophenol (DCP), As(3+), Cr(6+) are tested and the detection limits are 3.2, 25, and 3.2 ppm, respectively. Moreover, we could identify the yellow green to dark green color change by naked eye even at concentrations as low as 12.5 ppm for both DCP and Cr(6+). Subsequently, the acute toxicities of groundwater and south lake water are successfully determined by this sensor. This biosensor is rapid, sensitive and cost-effective, and can thus be regarded as a promising biosensor for giving an early warning of acute water toxicity.

关键词