2013

Impedimetric sensor for toxigenic Penicillium sclerotigenum detection in yam based on magnetite-poly(allylamine hydrochloride) composite.

Journal of colloid and interface science Silva GJ, Andrade CA, Oliveira IS, de Melo CP, Oliveira MD
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

We describe a new DNA biosensor for the detection of toxigenic Penicillium sclerotigenum in pure culture or infected yams. The P. sclerotigenum detection takes place on a self-assembled monolayer of a (magnetite)/(poly(allylamine hydrochloride)) (Fe3O4-PAH) composite that serves as an anchoring layer for the DNA hybridization interaction. Electrical impedance spectroscopy (EIS) was used to evaluate and quantify the hybridization degree. The Fe3O4-PAH composite is a good platform for the immobilization of biomolecules, due to the presence of many possible binding sites for nucleotides and to its large surface-to-volume ratio and good biocompatibility. The biosensor was capable of not only qualitatively detecting the presence of the fungus genome at low concentrations, but also shown a good quantitative impedimetric response its electrical resistance was monitored along the time of exposure. A Fe3O4-PAH-probe biosensor would require only small volumes and low concentrations of the analyte when used, for instance, in detecting P. sclerotigenum contamination of food, besides presenting many comparative advantages, such as selectivity, specificity and reproducibility, relative to alternative techniques.

关键词