2013

Microbial fuel cell type biosensor for specific volatile fatty acids using acclimated bacterial communities.

Biosensors & bioelectronics Kaur A, Kim JR, Michie I, Dinsdale RM, Guwy AJ, Premier GC, Sustainable Environment Research Centre (SERC)
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Volatile fatty acid (VFA) concentration is one of the most important parameters for monitoring bio-processes such as anaerobic digestion and microbial fuel cells. In this study the correlation between VFA concentration and current/voltage responses and electrochemical properties by using the MFC technology was evaluated. The discrimination between different species of VFA by using two methods i.e., coulombic efficiency and cyclic voltammetry was investigated. Columbic efficiency gave a slow response of greater than 20h, particularly at concentration levels of 20mgl(-1). By using cyclic voltammetry to measure the oxidation peak at a consistent scan rate showed linear correlation to VFA concentration and peak current produced, up to <40mgl(-1)) in a rapid response time of 1-2min. The results presented showed good correlations between the individual VFA species concentration and charge, and also current generated. A MFC based biosensor array was produced capable of measuring individual acetate, propionate and butyrate concentrations with sensitivity down to 5mgl(-1) and up to 40mgl(-1).