2013

An amperometric acetylcholine biosensor based on a conducting polymer.

International journal of biological macromolecules Kanik FE, Kolb M, Timur S, Bahadir M, Toppare L
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

An amperometric acetylcholine biosensor was prepared by the generation of the conducting polymer poly(4-(2,5-di(thiophen-2-yl)-1H-pyrrol-1-yl)benzenamine) (poly(SNS-NH2)) on graphite electrodes. For pesticide detection, the enzymes acetylcholinesterase (AChE) and choline oxidase (ChO) were co-immobilized onto the conducting polymer poly(SNS-NH2) films using covalent binding technique. Electrochemical polymerization was carried out using a three-electrode cell configuration via cyclic voltammetry. Characterization of resulting acetylcholine biosensor was done in terms of optimum pH, enzyme loading, range of linear response and shelf-life. Linear range was 0.12-10mM and shelf-life 4 weeks. Sensitivity was calculated as 2.19μAmM(-1)cm(-2). The designed biosensor was tested for the determination of paraoxon-ethyl in spiked tap water samples. The results were compared with a conventional quantification method using HPLC-DAD. Linear correlation of the quantification results with both methods (R(2)=0.998) was obtained.

关键词