2013

Enzyme-free and ultrasensitive electrochemical detection of nucleic acids by target catalyzed hairpin assembly followed with hybridization chain reaction.

Biosensors & bioelectronics Liu S, Wang Y, Ming J, Lin Y, Cheng C, Li F
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

An isothermal, enzyme-free and ultrasensitive protocol for electrochemical detection of DNA is proposed based on the ingenious combination of target catalyzed hairpin assembly and hybridization chain reaction (HCR) strategies for two-step signal amplification. The DNA hairpin assembly on the electrode is triggered by target DNA, accompanied by the release of target DNA for the successive hybridization and assembly process. The newly emerging DNA fragment on the electrode after hairpin assembly is further used to propagate the HCR between methylene blue-labeled signal probe and auxiliary probe, inducing a remarkably amplified electrochemical signal. The current dual signal amplification strategy is relatively simple and inexpensive owing to avoid the use of any kind of enzyme or sophisticated equipment. It can achieve a sensitivity of 0.1 fM with a wide linear dynamic range from 1 × 10(-15) to 1 × 10(-10)M and discriminate mismatched DNA from perfect matched target DNA with a high selectivity. The high sensitivity and selectivity make this method a great potential for early diagnosis in gene-related diseases.

关键词