Graphene oxide-cobalt phthalocyanine (GO-PcCo) hybrid material as a new electrocatalyst was synthesized and used successfully to fabrication of new biosensor for the electrooxidation of l-cysteine (CSH) in aqueous media. Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), and transmission electron microscopy (TEM) images revealed that cobalt phthalocyanine is covalently attachment on graphene oxide sheets as single layers GO-PcCo. Cyclic voltammetric studies showed that the GO-PcCo/glassy carbon electrode (GO-PcCo/GCE) improves electrochemical behavior of CSH oxidation, as compared to the GO and PcCo. In addition, the results indicated that GO and PcCo have a synergic effect in the electrooxidation of CSH. The catalytic oxidation responses were studied and the reaction mechanisms were discussed. The electrocatalytic behavior is further developed as a new detection scheme for CSH by chronoamperometry method and under optimized conditions, excellent analytical features, including high sensitivity and selectivity, low detection limit and satisfactory dynamic range, were achieved.