2013

Direct electrochemistry of hemoglobin immobilized on the water-soluble phosphonate functionalized multi-walled carbon nanotubes and its application to nitric oxide biosensing.

Talanta Li P, Ding Y, Lu Z, Li Y, Zhu X, Zhou Y, Tang Y, Chen Y, Cai C, Lu T
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The direct electron transfer and electrocatalysis of hemoglobin (Hb) immobilized on the phosphonate functionalized multi-walled carbon nanotubes (MWCNTs) are investigated. Fourier transform infrared (FT-IR) spectra, UV-vis spectra and cyclic voltammetry (CV) analyses reveal that the phosphonate functionalized MWCNTs have good biocompatibility for Hb immobilization, and promote the electron communication between Hb and electrode. The immobilized Hb shows a pair of redox peak with a formal potential of -406 ± 10 mV (vs. SCE) and the electrochemical behavior of Hb was a surface-controlled process in a pH 7.0 phosphate buffer solution. And the immobilized Hb can act in an electrocatalytic manner in the electrochemical reduction of nitric oxide (NO). Accordingly, an unmediated NO electrochemical biosensor is constructed. Under optimized experimental conditions, the NO electrochemical biosensor shows the fast response (less than 3s), the wide linear range (1.5 × 10(-7) to 2.7 × 10(-4)M) and the low detection limit (1.5 × 10(-8)M), which is attributed to the good mass transport, the large Hb loading per unit area and the fast electron transfer rate of Hb.

关键词